Process of Industrial RO Plant |
|
RAW WATER PUMP:-
To generate the pressure for down the line system.
PRESSURE SAND FILTER (PSF):-
The water is first filtered by Pressure sand filter Unit for removal of suspended matters and turbidity.
ACTIVATED CARBON FILTER(ACF):-
To remove Colour, Odour, Chlorine, Oil & Grease from the raw water.
MICRON CARTRIDGE FILTER(MCF):-
These are Pressure Vessels Fitted internally with spun or pleated cartridge element which removes micron sized particles.
ANTISCALANT DOSING SYSTEM:-
To prevent membrane from scaling (hardness).
HIGH PRESSURE PUMP:-
A high pressure pump is provided for supplying the feed water to RO System at high pressure of 10 - 12 kg/cm2.
DESALINATION SYSTEM BY RO MEMBRANE ELEMENT :-
A Reverse Osmosis System rejects 90-95% of Total Dissolved Solids (TDS).
STORAGE OF TREATED(PURE) WATER:-
To store Treated (pure) water in tank. |
|